The Protection That Is Not a Device

The only backflow protection with no moving part, the only one that cannot fail mechanically, and the easiest one in the world to ruin.

Call (888) 764-9890

Steel manifold fitted with pressure gauges

Free to homeowners in The Protection That Is Not a Device — the contractor pays us for the introduction, you never do.

Key point

EPA requires an air gap to be twice the supply pipe diameter and never less than one inch. It is the only protection with no moving part and the only one that cannot stick or corrode, and EPA still requires air gaps to be inspected as frequently as mechanical backflow preventers.

Source: U.S. EPA, Cross-Connection Control Manual, EPA 816-R-03-002, February 2003.

It is the highest protection in EPA’s manual, it costs nothing, and the way it fails has nothing to do with hardware.

What this site is

CrossConnect is a referral service, not a contractor. We connect property owners and managers with independent contractors. Backflow assembly testing is normally restricted to testers holding a specific certification and using calibrated equipment, and the report usually has to reach your water purveyor — ask to see the certification and ask who files the report. We carry out no testing, we certify nobody, we do not set prices, and we never charge callers anything. Nothing here selects a device for any installation or states that any assembly is passing.
What an air gap is measured between, and how it is lostTwo drawings of the same arrangement. On the left, a supply outlet ends in free air above the rim of a basin, and the vertical distance between the outlet and the rim is dimensioned as twice the supply pipe diameter and never less than one inch. On the right, the identical fitting has a hose attached which hangs down into the basin, so there is no longer any separation between the supply and whatever the basin holds.flood level rim2 × D, never under 1 inan air gapa hose, and thegap is goneno air gap at all
It is the only backflow protection with nothing to fail, and the only one a person can destroy without tools. The measurement runs from the outlet of the supply to the flood level rim — not to the water, and not to the bottom of the basin.

The dimension

EPA states it directly: an air gap must be twice the supply pipe diameter but never less than one inch.

2 × D, minimum 1 inchthe vertical separation between the outlet of a supply and the flood level rim of the vessel receiving it

Two numbers, both easy to check with a ruler, and between them they are the strongest protection in the manual.

Source: U.S. EPA, Cross-Connection Control Manual, EPA 816-R-03-002, February 2003.

Why it beats every mechanical device

Because there is nothing to fail. A check valve can foul on a grain of grit and hold slightly open. A relief port can be blocked. A spring can weaken. An air gap is a distance, and distances do not stick, corrode or need a test kit.

It addresses both backsiphonage and backpressure for the same reason: there is no continuous path, so neither a vacuum nor a pressure has anything to act along.

And how it fails anyway

Somebody closes it. A hose is pushed further down. A pipe is extended. A vessel is filled higher than its rim. A flexible line is left hanging into what it is filling.

The failure mode is a person, not a part. Which is why EPA is explicit that air gaps must be inspected as frequently as mechanical backflow preventers — the one protection with nothing to wear out still needs looking at, because the thing that ruins it is somebody being helpful.

Where you already have one

Above a sink, if the faucet spout ends well clear of the rim. On a dishwasher, in that small chrome fitting on the countertop that most people assume is decorative. On many appliance fills.

They are common, they are invisible once you stop noticing them, and they are doing real work.

The thing to watch for

Any arrangement where a supply outlet has been brought down to, or below, the level of what it is filling. A hose in a tank. A fill line into a vessel. A tap with an extension on it reaching into a container.

The most common version of this is in a yard, and several of EPA’s case histories are exactly it.

Know what is on the tag before you call.Make, model, size and the date of the last test are usually stamped or tagged on the assembly itself, and they decide which test kit and which paperwork the visit needs. We will route you to somebody who covers your area, selected on the ZIP code of the property, and you are never charged. Backflow is our specialty, though the number will take any plumbing request on the property.